System planning & quotes

Plan and budget a make-up air system

Compare quotes at the same design airflow. Ask where outdoor air enters, how it reaches the kitchen, and how the installer will demonstrate that the system works.

Trace the incoming air path

Outdoor intakeConfirm a permitted location and the components specified for the unit.
Damper & duct pathCheck how the damper responds to the hood and what resistance the route adds.
Delivery to the kitchenCheck the proposed outlet or permanent connections to the kitchen.
Conceptual flow from outdoors to kitchen. The diagram does not depict appliance venting or a site-specific design.

Model IRC M1503.6.1 addresses delivery in the exhaust room or through permanent openings connecting it with another room or duct system. Ask about drafts and how the proposed outlet interacts with the hood's capture zone. For a central air-handler connection, have the installer check the equipment manual, approved outdoor air conditions and control sequence. Code sources and local variation

Size from performance data

Ask for the target delivered supply airflow, the design pressure, and the rated performance of the intake, damper and any fan at that condition. A passive damper opens an air path; its opening diameter alone does not tell you how much air passes. A powered system also needs a performance check through the actual route. Broan damper size and configuration examples (PDF)

Do not use the exhaust duct velocity comparison as a supply-system sizing table. The design airflow, restrictions and available pressure must all be checked for the supply side.

Estimate the winter sensible load

For an illustrative supply of 600 CFM warming from 10°F to 68°F, the sensible heat rate is about 37,600 Btu/h (1.08 × 600 × 58), using 60 min/h, air density 0.075 lb/ft³ and specific heat 0.24 Btu/(lb·°F). This is a load estimate for that airflow and temperature rise, before equipment selection. It excludes humidity effects, altitude adjustment, distribution losses and runtime or utility costs.

Compare what each quote includes

Line itemAsk the contractor to specify
Supply equipmentIntake, damper, any fan or tempering equipment, and performance at the proposed design point.
InstallationDuct route, openings and repair, controls, electrical work, applicable permit fees, and exclusions.
VerificationAirflow, interlock operation and any required testing or balancing. Request the results in writing.

Get local itemized prices tied to the same route and documented airflow. Ask separately about the exhaust hood and duct if they are in the same quote.

Questions to take to the estimate visit

  • Which locally adopted requirement and airflow basis is the quote using?
  • How will the hood start or open the supply system at the relevant speeds?
  • What will the installer measure after installation, and who handles the permit or inspection?