Electronic settingFind the exact model and documented maximum after activation.
Matched accessoryVerify the hood and accessory pair plus the specified duct configuration.
Lab airflow ratingRecord the speed and test pressure. Another rating may describe a different condition.
Documented U.S. model examples
| Model | Manufacturer states | What to verify |
|---|---|---|
| Zephyr Podestà ZPO-E30AS / ZPO-E36AS | Model documents show a 600 CFM maximum and ACT options of 390 or 290 CFM. | Match your model and confirm which ACT setting was selected. The manual says a set limit cannot be reverted. Product page · Specifications & Documents |
| Broan PM400SSV / PM600SSV | The CRT manual lists a 300 CFM option for PM400SSV and 400 or 300 CFM options for PM600SSV. | Confirm the selected setting and corresponding CRT label. Document 1105025E describes an irreversible change. Installation guide, CRT section (PDF) |
| Broan PM390 family | Spec 99043887E lists high-speed airflow of 390 CFM at 0.10 in. w.g. and 375 CFM at 0.25 in. w.g. It separately lists a 440 max blower CFM figure. | These are different rating conditions. Ask which rating applies to your review before entering the hood's capacity. PM390 family spec |
| Bosch HUI56551UC + HUIRED56UC | The U.S. hood spec lists the matching reducer kit and states under 300 CFM with the accessory. | Match both part numbers and verify the manual's installation requirements. Confirm availability and local acceptance. U.S. hood spec |
What a lower rating changes
A documented limit may change the airflow your local authority considers. It can also change capture performance. Check the range manufacturer's requirements and hood coverage for how you cook. Running a hood on low or restricting it with an unapproved duct reducer does not establish a new documented rating.
Take these records to the building department
- Hood model and manufacturer document showing the relevant airflow value and test condition.
- Documented setting or accessory, including how the installer will record or label it.
- Duct arrangement and list of fuel-burning appliances with their venting and locations.