Worked example · a 600 CFM hood on a 6-inch duct
For a 36-inch cooktop against a wall, the HVI width guide gives a starting point of 300 CFM. If the selected hood is documented at 600 CFM, the duct screen uses that capacity. A 6-inch round duct has about 0.196 ft² of area, so 600 ÷ 0.196 is about 3,056 FPM. The calculated velocity assumes all 600 CFM is moving through that duct. Delivered airflow depends on the fan and the installed duct resistance. HVI sizing guide
If there's also a draft-hood water heater inside the dwelling's air barrier, the 2024 model IRC makes the make-up air condition relevant. If the vent type is unknown, confirm it first. Bring the hood's model and manual, the duct route, and the appliance's venting details to your building department. Read the model rule.
Before you order
- Find the exact model, its airflow rating and test conditions, and any documented factory limit. For professional-style ranges, follow the cooktop maker's ventilation guidance.
- Match the permitted duct size, material, fittings and termination in the hood manual. Use the duct worksheet to record what you have.
- Check the adopted code edition, local amendments and the installed combustion appliances. Ask whether the authority accepts the specific hood configuration and how it evaluates the exhaust rating.